Submitted by sfatula on Fri, 03/26/2010 - 19:06
So, when I click to add a lm_sensor to the system and server status webmin module, I am presented with a list of sensors in a drop down menu. Not on that list is my fans. Doing a sensors command on my system yields:
[root@neoprod webmin]# sensors
w83627hf-isa-0290
Adapter: ISA adapter
in0: +3.39 V (min = +0.00 V, max = +4.08 V)
in1: +3.49 V (min = +0.00 V, max = +4.08 V)
in2: +0.94 V (min = +2.82 V, max = +3.79 V)
in3: +3.06 V (min = +3.14 V, max = +3.52 V)
in4: +1.23 V (min = +3.28 V, max = +0.30 V)
in5: +1.54 V (min = +1.34 V, max = +3.15 V)
in6: +1.86 V (min = +1.33 V, max = +2.48 V)
in7: +3.38 V (min = +2.59 V, max = +2.88 V)
in8: +0.26 V (min = +2.75 V, max = +3.68 V)
temp1: +49.0°C (high = +50.0°C, hyst = +45.0°C) sensor = thermistor
temp2: +33.5°C (high = +80.0°C, hyst = +75.0°C) sensor = thermistor
temp3: +33.5°C (high = +80.0°C, hyst = +75.0°C) sensor = thermistor
cpu0_vid: +0.000 V
beep_enable:enabled
w83793-i2c-0-2f
Adapter: SMBus I801 adapter at 1100
VcoreA: +1.24 V (min = +0.92 V, max = +1.49 V)
VcoreB: +1.26 V (min = +0.92 V, max = +1.49 V)
in2: +1.21 V (min = +1.08 V, max = +1.33 V)
in3: +0.50 V (min = +0.38 V, max = +0.69 V)
in4: +1.49 V (min = +1.34 V, max = +1.65 V)
in5: +3.28 V (min = +2.96 V, max = +3.63 V)
in6: +0.97 V (min = +0.90 V, max = +1.10 V)
+5V: +5.12 V (min = +4.52 V, max = +5.50 V)
5VSB: +5.12 V (min = +4.52 V, max = +5.50 V)
Vbat: +3.23 V (min = +2.70 V, max = +3.30 V)
fan1: 5335 RPM (min = 712 RPM)
fan2: 5018 RPM (min = 712 RPM)
temp1: +28.2°C (high = +75.0°C, hyst = +70.0°C) sensor = thermal diode
temp2: +32.2°C (high = +75.0°C, hyst = +70.0°C) sensor = thermal diode
temp3: +26.8°C (high = +75.0°C, hyst = +70.0°C) sensor = thermal diode
temp4: +29.8°C (high = +75.0°C, hyst = +70.0°C) sensor = thermal diode
temp5: +47.0°C (high = +50.0°C, hyst = +45.0°C) sensor = thermistor
beep_enable:disabled
I am guessing it has something to do with the first set of numbers where there is no fan. For whatever board that is. But it is not the MB. So, you can see in the second section, that the fans show up, both of them.
In the dropdown menu is no fans. I DO, however, see the temp values from BOTH sections of the sensors report. Just not the fans. See attached screen capture.
I really wanted to add a fan problem report.
Status:
Closed (fixed)
Comments
Submitted by JamieCameron on Sat, 03/27/2010 - 02:22 Comment #1
Thanks for the bug report - the issue is that Webmin doesn't properly parse that fan RPM line.
I will fix this in the 1.520 Webmin release.
Submitted by Issues on Sat, 04/10/2010 - 19:20 Comment #2
Automatically closed -- issue fixed for 2 weeks with no activity.